10
For Frontel Format
1. With the display showing FORMAT:, press either arrow
button until FRONTEL is displayed, then press
YES.
2. With the display showing PHONE PREFIX:, enter the
required prex (such as a 9 with a pause for outside
line access) +
YES or press ESC/NO if no prex is
required.
Note: To program a pause, press the @ button six times
for the # sign. Each # entry adds a 2-second pause.
3. With the display showing SUBSCRIBER NB: enter the
subscriber (account) number, (up to 16 digits), then
press
YES.
4. With the display showing FRONTEL NBR 1:, enter the
primary phone number the control panel will dial rst
to send reports to Frontel Automation Software
supported central stations, then press
YES.
5. With the display showing FRONTEL NBR 2:, press
ESC/NO to skip to the next step, or enter the secondary
phone number the control panel will dial to send
reports if attempts using the primary number are
unsuccessful, then press
YES.
6.
With the display showing FRONTEL IP 1:, enter the
primary IP number 010.000.000.016, then press
YES.
7. With the display showing FRONTEL IP 2:, enter the
secondary IP number 010.000.000.031, then press
YES.
8. With the display showing PERIODIC TEST: 24 HOURS,
press either arrow button to select the desired interval
(1 hour, 12 hours, 24 hours, 48 hours, 7 days, or No Test)
the control panel reports a phone communication test
to the central monitoring station, then press
YES.
Note: If you select No Test and press YES, the next
menu prompt (CODE/STATE MODIFICATION?) appears.
9. With the display showing TEST HOUR: press YES to
accept the default hour displayed, or press either arrow
button until the desired hour is displayed, then press
YES.
10. With the display showing TEST (MINUTES): press YES
to accept the default minutes displayed, or press either
arrow button until the desired minute is displayed,
then press
YES.
For Combined Format
Surtec+Frontel, Contact ID+Frontel,
Surtec+Video, Contact ID+Video:
1. With the display showing FORMAT:, press either
arrow button until the desired combination format is
displayed, then press
YES.
2. With the display showing PHONE PREFIX:, enter the
required prex (such as a 9 with a pause for outside line
access) +
YES or press ESC/NO if no prex is required.
Note: To program a pause, press the @ button six times
for the # sign. Each # entry adds a 2-second pause.
3. With the display showing SUBSCRIBER NB: enter the
subscriber (account) number, (8 digits for Surtec for
mats, 4 digits for Contact ID formats), then press
YES.
4.
With the display showing PHONE NBR 1: enter the
primary central station phone number the control
panel will dial rst to send reports, then press
YES.
5.
With the display showing PHONE NBR 2: press ESC/NO
to skip to the next step, or enter the secondary phone
number the control panel will dial to send reports if
attempts using the primary number are unsuccessful,
then press
YES.
6.
With the display showing FRONTEL NBR 1: enter the
primary phone number the control panel will dial rst
to send reports to Frontel Automation Software
supported central stations, then press
YES.
7. With the display showing FRONTEL NBR 2: press
ESC/NO to skip to the next step, or enter the secondary
phone number the control panel will dial to send reports
if attempts using the primary number are unsuccessful,
then press
YES.
8.
With the display showing FRONTEL IP 1: enter the primary
IP number 010.000.000.016, then press YES.
9.
With the display showing FRONTEL IP 2: enter the
secondary IP number 010.000.000.031, then press
YES.
10. With the display showing PERIODIC TEST: 24 HOURS,
press either arrow button to select the desired interval
(1 hour, 12 hours, 24 hours, 48 hours, 7 days, or No
Test) the control panel reports a phone communication
test to the central monitoring station, then press
YES.
Note: If you select No Test and press YES, the next
menu prompt (CODE/STATE MODIFICATION?) appears.
11. With the display showing TEST HOUR: press YES to
accept the default hour displayed, or press either arrow
button until the desired hour is displayed, then press
YES.
12.
With the display showing TEST (MINUTES): press YES
to accept the default minutes displayed, or press either
arrow button until the desired minute is displayed,
then press
YES.
Initial Configuration/Programming
Installation Sequence