Power Up Control Panel
and Clear Memory
For new installations, always clear the control panel memory
after powering it up for the rst time, and before program-
ming any devices or other system information.
1. Remove the end
screws on the control
panel to remove its
cover and install the
batteries. The LED ashes
once after the second
battery is installed.
Note: The control panel cover
must remain off for programming.
2. Mount the control panel
at its intended location using
the four mounting holes.
3. Clear control panel
memory by using a paper
clip end. Press and hold
the program button and
wait for the LED to
ash twice, then
release the button.
Programming an Alphanumeric
Keypad into the Control Panel
An alphanumeric keypad must be programmed into the control
panel rst, in order to perform any on-site programming.
Note: The control panel assigns alphanumeric keypads to
Area 1 (Entry/Exit Delay) automatically and does not prompt
you to assign it manually.
1. Install batteries into keypad
by removing the bottom screw
and separating the base
and keypad.
2. Re-attach base with screw.
Note After installing keypad
batteries, the keypad LED
remains on if the wall tamper
is not pushed in (closed).
The tamper state does not
affect programming.
3. Put the control panel into
program mode by pressing
and releasing the program button once using a paper clip
end. The LED ashes once.
4. On the alphanumeric key-
pad, press and hold the CLR
and ESC/NO buttons together
for one second, then release
them.
Wait for the keypad display
to show KEYBOARD 1 RE-
CORDED.
5. Press YES. The display
shows RADIO RANGE TEST?
6. Press YES. The display shows
REQUEST IS BEING SENT,then TEST IN PROGRESS.
The keypad LED starts ashing once every second.
7. Take the keypad to its intended mounting location and
make sure the LED ashes continuously, indicating good
communication with the control panel.
8. Press Yes to end the radio range test, then press ESC/NO.
The display shows the following messages: ENTER THE
INSTALLER CODE 4 TO 6 DIGITS THEN YES. The display
shows CONFIRM CODE. Re-enter the installer code and press
yes.
Screw
CLR and ESC/NO Buttons
6
Installation Sequence
Screw
INIT Button
LED
(8 seconds)
Commentaires sur ces manuels